Tue, Oct 06 · 01:59 AM CDTCVE-2015-0987
10.0/10 · Must read/watchNVDvuln
Summary
Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 rely on cleartext password transmission, which allows remote attackers to obtain sensitive information by sniffing the network during a PLC unlock request.
CVECVE-2015-0987
SeverityCRITICAL
TypeUPDATED
PublishedTue, Oct 06 · 01:59 AM CDT
ModifiedTue, Jun 02 · 09:16 PM CDT
Mon, Feb 13 · 09:59 PM CSTCVE-2016-9361
9.8/10 · Must read/watchNVDvuln
Summary
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions
CVECVE-2016-9361
SeverityCRITICAL
TypeUPDATED
PublishedMon, Feb 13 · 09:59 PM CST
ModifiedTue, Jun 02 · 08:16 PM CDT
Mon, Feb 13 · 09:59 PM CSTCVE-2016-9366
9.8/10 · Must read/watchNVDvuln
Summary
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions
CVECVE-2016-9366
SeverityCRITICAL
TypeUPDATED
PublishedMon, Feb 13 · 09:59 PM CST
ModifiedTue, Jun 02 · 08:16 PM CDT
Mon, Feb 13 · 09:59 PM CSTCVE-2016-9369
9.8/10 · Must read/watchNVDvuln
Summary
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions
CVECVE-2016-9369
SeverityCRITICAL
TypeUPDATED
PublishedMon, Feb 13 · 09:59 PM CST
ModifiedTue, Jun 02 · 08:16 PM CDT
Mon, Jun 03 · 07:29 PM CDTCVE-2017-14728
9.8/10 · Must read/watchNVDvuln
Summary
An authentication bypass was found in an unknown area of the SiteOmat source code. All SiteOmat BOS versions are affected, prior to the submission of this exploit. Also, the SiteOmat does not force administrators to switch passwords, leaving SSH and HTTP remote authentication open to public.
CVECVE-2017-14728
SeverityCRITICAL
TypeUPDATED
PublishedMon, Jun 03 · 07:29 PM CDT
ModifiedTue, Jun 02 · 08:16 PM CDT
Mon, Jun 03 · 07:29 PM CDTCVE-2017-14851
9.8/10 · Must read/watchNVDvuln
Summary
A SQL injection vulnerability exists in all Orpak SiteOmat versions prior to 2017-09-25. The vulnerability is in the login page, where the authentication validation process contains an insecure SELECT query. The attack allows for authentication bypass.
CVECVE-2017-14851
SeverityCRITICAL
TypeUPDATED
PublishedMon, Jun 03 · 07:29 PM CDT
ModifiedTue, Jun 02 · 08:16 PM CDT
Tue, Jul 24 · 05:29 PM CDTCVE-2018-10627
9.8/10 · Must read/watchNVDvuln
Summary
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. An attacker can use the SOAP API to retrieve and change sensitive configuration items such as the usernames and passwords for the Web and FTP servers. This vulnerability does not
CVECVE-2018-10627
SeverityCRITICAL
TypeUPDATED
PublishedTue, Jul 24 · 05:29 PM CDT
ModifiedTue, Jun 02 · 08:16 PM CDT
Tue, Jul 24 · 05:29 PM CDTCVE-2018-8851
9.8/10 · Must read/watchNVDvuln
Summary
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices store passwords in plaintext, which may allow an attacker with access to the configuration file to log into the SmartServer web user interface.
CVECVE-2018-8851
SeverityCRITICAL
TypeUPDATED
PublishedTue, Jul 24 · 05:29 PM CDT
ModifiedTue, Jun 02 · 09:16 PM CDT
Tue, Jul 24 · 05:29 PM CDTCVE-2018-8855
9.8/10 · Must read/watchNVDvuln
Summary
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices allow unencrypted Web connections by default, and devices can receive configuration and firmware updates by unsecure FTP.
CVECVE-2018-8855
SeverityCRITICAL
TypeUPDATED
PublishedTue, Jul 24 · 05:29 PM CDT
ModifiedTue, Jun 02 · 09:16 PM CDT
Tue, Jul 24 · 05:29 PM CDTCVE-2018-8859
9.8/10 · Must read/watchNVDvuln
Summary
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. An attacker can bypass the required authentication specified in the security configuration file by including extra characters in the directory name when specifying the directory
CVECVE-2018-8859
SeverityCRITICAL
TypeUPDATED
PublishedTue, Jul 24 · 05:29 PM CDT
ModifiedTue, Jun 02 · 08:16 PM CDT
Mon, Dec 16 · 08:15 PM CSTCVE-2019-18269
9.8/10 · Must read/watchNVDvuln
Summary
Omron’s CS and CJ series PLCs have an unrestricted externally accessible lock vulnerability.
CVECVE-2019-18269
SeverityCRITICAL
TypeUPDATED
PublishedMon, Dec 16 · 08:15 PM CST
ModifiedTue, Jun 02 · 09:16 PM CDT
Tue, Feb 26 · 11:29 PM CSTCVE-2019-9201
9.8/10 · Must read/watchNVDvuln
Summary
Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories.
CVECVE-2019-9201
SeverityCRITICAL
TypeUPDATED
PublishedTue, Feb 26 · 11:29 PM CST
ModifiedTue, Jun 02 · 09:16 PM CDT
Fri, May 28 · 04:15 PM CDTCVE-2020-15782
9.8/10 · Must read/watchNVDvuln
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS
CVECVE-2020-15782
SeverityCRITICAL
TypeUPDATED
PublishedFri, May 28 · 04:15 PM CDT
ModifiedTue, Jun 02 · 08:16 PM CDT
Wed, Sep 09 · 07:15 PM CDTCVE-2020-15786
9.8/10 · Must read/watchNVDvuln
Summary
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devic
CVECVE-2020-15786
SeverityCRITICAL
TypeUPDATED
PublishedWed, Sep 09 · 07:15 PM CDT
ModifiedTue, Jun 02 · 08:16 PM CDT
Tue, Feb 09 · 05:15 PM CSTCVE-2020-15798
9.8/10 · Must read/watchNVDvuln
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMIC
CVECVE-2020-15798
SeverityCRITICAL
TypeUPDATED
PublishedTue, Feb 09 · 05:15 PM CST
ModifiedTue, Jun 02 · 08:16 PM CDT
Wed, May 12 · 02:15 PM CDTCVE-2021-27384
9.8/10 · Must read/watchNVDvuln
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (Al
CVECVE-2021-27384
SeverityCRITICAL
TypeUPDATED
PublishedWed, May 12 · 02:15 PM CDT
ModifiedTue, Jun 02 · 08:16 PM CDT
Mon, Jun 03 · 08:29 PM CDTCVE-2017-14854
9.1/10 · Must read/watchNVDvuln
Summary
A stack buffer overflow exists in one of the Orpak SiteOmat CGI components, allowing for remote code execution. The vulnerability affects all versions prior to 2017-09-25.
CVECVE-2017-14854
SeverityCRITICAL
TypeUPDATED
PublishedMon, Jun 03 · 08:29 PM CDT
ModifiedTue, Jun 02 · 08:16 PM CDT
Wed, Jan 06 · 03:15 PM CSTCVE-2020-27285
9.1/10 · Must read/watchNVDvuln
Summary
The default configuration of Crimson 3.1 (Build versions prior to 3119.001) allows a user to be able to read and modify the database without authentication.
CVECVE-2020-27285
SeverityCRITICAL
TypeUPDATED
PublishedWed, Jan 06 · 03:15 PM CST
ModifiedTue, Jun 02 · 09:16 PM CDT
Mon, Jun 16 · 04:15 PM CDTCVE-2025-49794
9.1/10 · Must read/watchNVDvuln
Summary
A use-after-free vulnerability was found in libxml2. This issue occurs when parsing XPath elements under certain circumstances when the XML schematron has the schema elements. This flaw allows a malicious actor to craft a malicious XML document used as input for libxml, resulting in the program's crash using libxml or
CVECVE-2025-49794
SeverityCRITICAL
TypeUPDATED
PublishedMon, Jun 16 · 04:15 PM CDT
ModifiedTue, Jun 02 · 02:16 PM CDT
Mon, Jun 16 · 04:15 PM CDTCVE-2025-49796
9.1/10 · Must read/watchNVDvuln
Summary
A vulnerability was found in libxml2. Processing certain sch:name elements from the input XML file can trigger a memory corruption issue. This flaw allows an attacker to craft a malicious XML input file that can lead libxml to crash, resulting in a denial of service or other possible undefined behavior due to sensitive
CVECVE-2025-49796
SeverityCRITICAL
TypeUPDATED
PublishedMon, Jun 16 · 04:15 PM CDT
ModifiedTue, Jun 02 · 02:16 PM CDT
Mon, Feb 13 · 09:59 PM CSTCVE-2016-9365
8.8/10 · Worth your timeNVDvuln
Summary
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions
CVECVE-2016-9365
SeverityHIGH
TypeUPDATED
PublishedMon, Feb 13 · 09:59 PM CST
ModifiedTue, Jun 02 · 08:16 PM CDT
Wed, Feb 24 · 05:15 PM CSTCVE-2021-21974
8.8/10 · Worth your timeNVDvuln
Summary
OpenSLP as used in ESXi (7.0 before ESXi70U1c-17325551, 6.7 before ESXi670-202102401-SG, 6.5 before ESXi650-202102101-SG) has a heap-overflow vulnerability. A malicious actor residing within the same network segment as ESXi who has access to port 427 may be able to trigger the heap-overflow issue in OpenSLP service res
CVECVE-2021-21974
SeverityHIGH
TypeUPDATED
PublishedWed, Feb 24 · 05:15 PM CST
ModifiedTue, Jun 02 · 09:16 PM CDT
Mon, Mar 15 · 05:15 PM CDTCVE-2021-25667
8.8/10 · Worth your timeNVDvuln
Summary
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and = V4.3 and = V4.3 and = V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1)
CVECVE-2021-25667
SeverityHIGH
TypeUPDATED
PublishedMon, Mar 15 · 05:15 PM CDT
ModifiedTue, Jun 02 · 08:16 PM CDT
Mon, Jun 03 · 07:29 PM CDTCVE-2017-14852
8.6/10 · Worth your timeNVDvuln
Summary
An insecure communication was found between a user and the Orpak SiteOmat management console for all known versions, due to an invalid SSL certificate. The attack allows for an eavesdropper to capture the communication and decrypt the data.
CVECVE-2017-14852
SeverityHIGH
TypeUPDATED
PublishedMon, Jun 03 · 07:29 PM CDT
ModifiedTue, Jun 02 · 08:16 PM CDT
Mon, Jun 03 · 07:29 PM CDTCVE-2017-14853
8.6/10 · Worth your timeNVDvuln
Summary
The Orpak SiteOmat OrCU component is vulnerable to code injection, for all versions prior to 2017-09-25, due to a search query that uses a direct shell command. By tampering with the request, an attacker is able to run shell commands and receive valid output from the device.
CVECVE-2017-14853
SeverityHIGH
TypeUPDATED
PublishedMon, Jun 03 · 07:29 PM CDT
ModifiedTue, Jun 02 · 08:16 PM CDT